BZHPR - INDIUM IN 111 CHLORIDE STERILE SOLUTION
- MSDS: BZHPR
- Manufacturer: MALLINCKRODT MEDICAL INC
- Product Name: INDIUM IN 111 CHLORIDE STERILE SOLUTION
- National Stock Number: 6505-00N065745
Product Identification
Product ID:INDIUM IN 111 CHLORIDE STERILE SOLUTION
MSDS Date:01/01/1995
FSC:6505
NIIN:00N065745
MSDS Number: BZHPR
Responsible Party
MARYLAND HEIGHTS, MO 63043
US
Emergency Phone: 800-424-9300(CHEMTREC)
Info Phone: 314-770-7800
Cage: FO650
Contractor
Telephone: 314-770-7800/314-895-2000
Cage: FO650
Ingredients
CHLORIDES; (INDIUM CHLORIDE IN-111)
CAS: 50800-85-6
Fraction By Weight: <1%
OSHA PEL N/K
ACGIH TLV: N/K
HYDROCHLORIC ACID; (HYDROGEN CHLORIDE) (SARA 302/313)
CAS: 7647-01-0
RTECS: MW4025000
Fraction By Weight: <1%
OSHA PEL 5 PPM, C
ACGIH TLV: 5 PPM, C
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: >99.9%
OSHA PEL N/K
ACGIH TLV: N/K
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHAL:INDIUM CHLORIDE DOES NOT
EASILY BECOME AIRBORNE. NOT EXPECTED TO BE HLTH HAZ VIA INHAL.
INGEST:MAY CAUSE ASYMPTOMATIC PHYSIOLOGICAL UPTAKE BY SPECIFIC
TARGET ORGANS OR TISSUES. SKIN CONT:N OT EXPECTED TO PRDCE ANY
ACUTE ADVERSE HLTH EFTS. EYE CONT:NO ADVERSE EFTS EXPECTED, BUT MAY
CAUSE MECH IRRIT. CHRONIC:HLTH RISKS ASSOC W/CHRONIC RADIA EXPOS
(CANCER, LEUKEMIA, GENETIC & TERATOGENIC E FTS) ARE BELIEVED TO
INVOLVE LEVELS OF RADIA EXPOS WHICH ARE MUCH HIGHER THAN THOSE
PERMITTED OCCUPATIONALLY. IT IS WIDELY ACCEPTED BYSCIENTIFIC
COMMUNITY THAT EXPOS TO SUFFICIENT QTYS OF IONIZING RAD IA CAN
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: POTNTLY CAUSE HARMFUL BIOLOGICAL EFTS
WHICH INCL CANCER, LEUKEMIA & GENETIC & TERATOGENIC EFTS. FOR
DETAILED TOXICOLOGICAL INFO ON SPECIFIC COMPONENTS, WRITE TO
REGULATORY COMPLAINTS DEPT.
Medical Cond Aggravated by Exposure:NO INFORMATION FOUND.
First Aid
First Aid:INGEST:CALL MD IMMED . INHAL:REMOVE TO FRESH AIR. SUPPORT
BRTHG (GIVE O*2/ARTF RESP) . SKIN:WASH AFFECTED AREA THORO W/SOAP &
WATER UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. ALWAYS BLOT DRY.
DO NOT ABRADE SKIN. NOTIFY RADIA SFTY PERS. EYE:WASH W/WATER FOR AT
LST 15 MINS/UNTIL NO MORE RADIOACTIVITY CAN BE REMOVED. NOTIFY
RADIA SFTY PERS. NOTE:INHAL/INGEST:NOTIFY RADIA SFTY PERS IMMED.
AMT OF MATL INHALED/INGESTED SHOULD BE ASSESSED & DOCUMENTED.
Fire Fighting
Extinguishing Media:USE ANY MEANS SUITABLE FOR EXTINGUISHING
SURROUNDING FIRE.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT CONSIDERED TO BE A FIRE OR EXPLOSION
HAZARD.
Accidental Release
Spill Release Procedures:IF PROD IS RECEIVED IN LEAKING CNDTN/ANY
LOSS/RELS OF RADIOACTIVE CONTENTS OCCURS, NOTIFY YOUR RADIA SFTY
DEPT & MFR AT (314)770-7800. ALL CLEANUP OPERATIONS SHOULD BE
PERFORMED ACCORDING TO STD OPERA TING PROCS (SOP'S) ESTABLISHED FOR
YOUR FACILITY & BY NRC/OTHER APPLIC LOC, STATE/FED REGS. BECAUSE
THIS PROD IS INTENDED FOR USE BY HOSPITALS & PATIENTS, IT IS
EXPECTED TO BE TREATED BY (SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AT 15C-30C. HNDLG TIME SHOULD BE
KEPT TO MIN & APPROP SHIELDING SHOULD BE USED. HNDLG DEVICES SUCH
AS SYRINGE SHIELDS & TONGS SHOULD BE USED.
Other Precautions:STOR & DISP OF PROD SHOULD BE CONTROLLED IN MANNER
WHICH IS IN COMPLIANCE W/APPROP REGS OF FED/STATE GOVT AGENCY
AUTHORIZED TO LICENSE USE OF THIS RADIONUCLIDE. NO SMOKING,
EATING/DRINKING SHOULD BE A LLOWED IN ANY AREA WHERE RADIOACTIVE
MATLS ARE HNDLD/STORED. CAUT! RADIOACTIVE MATL. READ PACKAGE IN
SERT (OTHER INFO)
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NOT EXPECTED TO REQUIRE PERSONAL RESPIRATOR
USAGE.
Ventilation:PROPERLY SEALED CONTAINERS ARE NOT EXPECTED TO REQUIRE ANY
SPECIAL VENTILATION.
Protective Gloves:DISPOSABLE PLASTIC, LATEX/RUBBER GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA . LABCOAT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC: STD WASTEWATER TREATMENT FACILITIES W/NO ADVERSE ENVIRON
IMPACTS. RQ: IN 111=100 CI; HYDROGEN CHLORIDE=5000 LBS. RELEVANT TO
AIR, LAND/WATER OF THES HAZ SUBSTANCES WHICH EXCEED RQ MUST BE
REPORTED TO NRC AT 800-424-8802. WASTE DISP METH: IF NOT
RADIOACTIVE/BIOHAZARD. WASTE INDIUM IN CHLORIDE (OTHER INFO)
Chemical Properties
Boiling Pt:B.P. Text:212F,100C
Melt/Freeze Pt:M.P/F.P Text:32.0F,0.0C
Spec Gravity:>50 MCI/UG
Solubility in Water:SOLUBLE
Appearance and Odor:CLEAR, COLORLESS LIQUID IN 3 ML GLASS VIAL;
ODORLESS.
Stability
Stability Indicator/Materials to Avoid:YES
NO INFORMATION FOUND.
Stability Condition to Avoid:STABLE UNDER ORDINARY CONDITIONS OF USE &
STORAGE.
Hazardous Decomposition Products:MAY EMIT RADIOACTIVE FUMES CONTAINING
IN-111 WHEN HEATED TO DECOMPOSITION.
Disposal
Waste Disposal Methods:INDIUM IN-111 CHLORIDE STERILE SOLN IS
RADIOACTIVE WASTE UNTIL ACTIVITY HAS DECAYED TO NONDETECTABLE
LEVELS. RADIOACTIVE WASTE MUST BE HNDLD I/A/W PROCS ESTABLISHED BY
YOUR RADIA SFTY OFFICER, NRC & O THER APPROP REGS. IF MED WASTE IS
INVOLVED, SUCH AS BLOOD, BLOOD PRESS/SHARPS, WASTE MUST BE HNDLD A
S BIOHAZARD & DISPOSED OF ACCORDINGLY. (SUPDAT)
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.